Power Supply | 6VDC~12VDC, 50mA Max(External power supply) |
Data Display | 4-digit LCD |
LCD Size | 47mm×28.5mm |
Resistance Range | 0.01Ω~100Ω |
Resolution | 0.001Ω |
Accuracy | ±2%rdg±3dgt(20℃±5℃, below 70%RH) |
PCB Size | 75mm×54mm×22mm |
Sensor Size | 110mm×80mm×55mm |
Perforation Size | 65mm×36mm |
Sensor Weight | About 568g |
PCB Interface | J1: Signal output, power input interface J2: Sensor and PCB connection port |
J1 Mark | P+: Power input positive P-: Power input ground GND: Signal ground,short circuited to power input ground (P-) R+: Signal output positive R-: Signal output negative |
J2 Mark | I+, I-current coil interface U+, U-voltage coil interface GND:common-ground |
Connection Cable | 1 PCS, length 0.5m (5-core wire) |
Signal Cable | 1PCS, length 1m (5-core wire) |
Alarm Setting | Detector panel button setting or Background software(developed) setting |
Alarm Threshold Setting Range | Resistance: 0Ω~500Ω (turn off the alarm function when set to 500) |
Communication Mode | RS485 or 4G communication (optional) |
Wiring Cable | Red---power input positive; black---power input ground;(the power input ground and the shielding ground can be connected with short circuit) Green---RS485 signal positive; yellow-green---RS485 signal negative; White---shielding ground; |
Overflow Indication | When the test value is greater than 100Ω, the LCD display the “0LΩ”symbol |
Measurement Range Gear Shift | Fully automatic shift |
Grounding Lead Interference Current | Should be avoided |
External Magnetic Field | <40A/m |
External Electric Field | <1V/m |
Single Measurement Time | About 0.5 second |
Working Current | 50mA Max. |
Install | The ground wire penetrate through the center hole of the sensor |
Installation Requirement | The circuit board need to be placed in another protective box |
Normal Version 4G | LTE-FDD B1/B3/B5/B8 LTE-TDD B34/B38/B39/B40/B41 |
Global Version 4G | LTE-FDD B1/B2/B3/B4/B5/B7/B8/B12/B13/B18/B19/B20/B25/B26/B28 LTE-TDD B38/B39/B40/B41 WCDMA B1/B2/B4/B5/B6/B8/B19 GSM B2/B3/B5/B8 |
Working Temperature & Humidity | -20℃~55℃;20%RH~90%RH |
Product Picture | Product Model Name | Clamp Jaw Size | Resistance Range | Clamp Jaw Structure | LCD Displayer | Alarm Function | Communication Method |
ETCR2800B Earth Resistance Online Detector | 60mm×28mm | 0.01Ω~200Ω | -- | Yes | RS485,4G(optional) | ||
ETCR2800C Earth Resistance Online Detector | 60mm×28mm | 0.01Ω~200Ω | Yes | Yes | RS485,4G(optional) | ||
ETCR2800KB Split-Core Earth Resistance Online Detector | 56mm×26mm | 0.01Ω~100Ω | Closed Loop | -- | Yes | RS485,4G(optional) | |
ETCR2800KC Split-Core Earth Resistance Online Detector | 56mm×26mm | 0.01Ω~100Ω | Closed Loop | Yes | Yes | RS485,4G(optional) | |
ETCR2800E Small Caliber Earth Resistance Online Detector | Φ17mm | 0.01Ω~100Ω | Small Caliber | Yes | Yes | RS485,4G(optional) | |
ETCR2800N Built-in Earth Resistance Online Detector | 66mm×36mm | 0.01Ω~100Ω | Built-In | Yes | Yes | RS485,4G(optional) | |
ETCR2800T Stainless Steel Earth Resistance Online Detector | 60mm×30mm | 0.01Ω~100Ω | Stainless Steel Housing | Yes | Yes | RS485,4G(optional) | |
ETCR2800X Large Caliber Earth Resistance Online Detector | 130mm×20mm | 0.01Ω~10Ω | Closed Loop | Yes | Yes | RS485,4G(optional) |