ETCR1220 Transformer Region Identify Meter

Main Functions
Used to online identify the attribution relationship between the transformer and user, and determine the network topology relationship.
Distance of test: 5km
Recognition cycle: 6s
Harmonic analysis: 2~34 times
Memory: data storage 9999 groups.
 
    Product Introduction
    ETCR1220 Transformer Region Identify Meter, also known as transformer region topology identification meter, transformer region dual-method identification meter, which is used for online identify the attribution relationship between transformer and user and to determine the network topology relationship. The instrument adopt with power frequency signal carrier modulation technology for transformer identification, accurate transformer identification can be achieved under the influence of adjacent transformer sharing the same voltage, ground, cable trench, and communication base station. The identification meter is consisted of handheld host and slave, host and slave are identical, which can be used on the secondary side or measured point of the transformer region, bidirectional identification of the transformer region.
    ETCR1220 Transformer Region Identify Meter adopts with a combination of high speed A/D AC sampling and high-speed DSP digital processing technology. Developed using power frequency carrier modulation technology, which provides an efficient and essential tool for power grid load survey, transformer region contracting, and electricity inspection and product scheduling. This product fully meets the need of transformer region recognition, user recognition, phase and phase sequence recognition. Compared with previous product, it has advantages such as full network coverage, fast recognition speed, accuracy, simple operation, and convenient portability.
    1.Bidirectional recognition function, the host and slave can be interchanged.
    2.Install up to 16 hosts at the same time to identify multiple transformer region recognition.
    3.Branch identification, clarifying the topological relationship of the transformer region, realizing branch power outages, local line loss verification, etc., is an important part of realizing the refined management of the transformer region, and supports up to 24 branch measurements.
    4.Transformer region mutual inspection, mutual inspection of transformer region is to detect whether exist the exist of crosstalk between adjacent transformers. some transformers may be connected to each other due to work negligence, resulting in the connection of lines between two transformers, and therefore it is necessary to conduct mutual testing between various transformers to ensure their independence.
    5.Harmonic analysis can view 34 times harmonic value.
    6.Record query, display the record of the attribution relationship of the transformer region.
    Technical Parameter
    Rated Voltage Three phase four wire: 220V (phase voltage)
    Rated Frequency 50Hz
    Normal Voltage Range 0.8Un~1.2Un
    Static Power Consumption Of The Meter ≤ 3.5W
    Test Distance 5km
    Identification Cycle 6 seconds
    One Recognition Success Rate >99%
    Electrical Parameter Accuracy ≤1%
    Phase Angle Test Range -179.9°~180.0°
    Harmonic Test Yes, 2~34 times
    Total Harmonic Distortion Yes, 2~34 times, each phase
    Memory 9999 groups
    Host Test Line Double lock 4 core test line (yellow, green, red, black)
    Slave Test Line Double lock 4 core test line (yellow, black), 220V test line (red, black)
    Large Alligator Clip 4 PCS
    Large Alligator Clip 4 PCS (with a hook)
    Small Alligator Clip 4 PCS
    Current Clamp Group 1 group (3 PCS)
    Meter Size 225mm×118mm×48mm
    Weight Instrument: about 730g×2 PCS; Total weight: about 1.7kg (include accessory)
    Insulation Between the instrument line and protective housing≥100MΩ
    Structure Double insulation, with insulated anti-vibration sheath
    Suitable Safety Standard GB/T 2423.10  GB/T 2423.2  GB/T 2423.1  GB/T 17626.11  GB/T 17626.5  GB/T 17626.8  GB311.3-83,IEC61010-031, IEC61010-1 CAT Ⅲ 600V
    Working Temperature & Humidity -30℃~70℃; below 80%RH
    Model comparison
    Product Picture Product Model Name Phase Line Identify Transformer Region Identify Branch Identify Harmonic Analysis Power Supply
    ETCR1100 Transformer Region Phase Line Identify Meter Yes     -- -- -- Lithium Battery
    ETCR1220 Transformer Region Identify Meter Yes     Yes     Yes     Yes     External Power Supply
    Data download
    Download:
Guangdong ETCR Electronic Technology CO.,Ltd
Our corporate focuses on the research, development, and production of intelligent power testing and control instruments; and also provides OEM service.
Guangdong ETCR Electronic Technology CO.,Ltd
Our corporate focuses on the research, development, and production of intelligent power testing and control instruments; and also provides OEM service.

info@etcr.net

(86-757)66860936

(+86)13802922567

Login
FollowUs
10th Floor, Block 5, Liandong Intelligent Manufacture Park, No. 105, Shilong North Road, Nanhai District, Foshan City, Guangdong, China
Guangdong ETCR Electronic Technology CO.,Ltd Copyright